Open hinged chiller door on a produce and dairy chiller room, staff stocking shelves inside

Chiller Doors

Insulated doors for rooms held between 0°C and +10°C, built to your opening at our works in Hosur.

  • 0°C to +10°CChiller rooms for produce, dairy and pharma
  • 60 / 80 mmPUF-insulated leaf, EPDM seal all round
  • 750 mm–3 mHinged, sliding and hatch, made to size
  • Since 1992Made in Hosur by the Alfa PEB group

What the door does

A chiller door is opened dozens of times a shift. Each part below is a reason the room stays cold between openings.

Hinged chiller door in a produce chiller room, a worker carrying a crate of lettuce past it
  • A 60 or 80 mm polyurethane core keeps the warm loading bay out of the room, so the compressor runs less.

  • An EPDM gasket presses against the frame all round, stopping the leaks that cause frost on the evaporator and water on the floor.

  • Above 0°C the seal does not freeze, so a chiller door skips the heated frame a freezer door needs. That makes it lighter and less expensive to run.

  • Heavy-duty hinges or a sliding track carry crates, trolleys and pallet trucks without the leaf sagging off its seal.

  • Smooth PPGI or SS 304 skins take daily cleaning in food and dairy rooms, with no grooves where water and dirt can collect.

  • Every door is built to the measured opening, from a 750 mm staff door to a 3 m wide sliding door for forklifts.

Five ways to open a chiller

Pick how goods move through the door. Each type opens differently and fits a different opening.

What goes inside your chiller?

Choose what you store and how it goes in. You get a starting door specification to send us.

You will store
Goods go in by

0°C to +10°C

Typical holding range for fruit & vegetables

Door
Hinged single door
Opening
750–1000 W × 2000–2400 H mm
Leaf and skin
60 mm PUF, PPGI both sides
Worth adding
Kick plate at trolley height
Send this on WhatsApp Or fill in the quote form

A starting point, not a final specification. Our team confirms it against your room and drawings.

The specification

What a chiller door is built from, and the sizes we make it in.

Cut-away of a chiller door leaf: white steel face, insulated foam core between two steel skins, EPDM gasket on the edge 60 mm Steel skinPPGI or SS 304 PUF / PIR coreFoamed in place EPDM gasketSeals all round
Suits most chillers held between +2°C and +10°C.

The leaf

Thickness
60 or 80 mm, 100 mm on request
Insulation
PUF or PIR, foamed in place
Skins
PPGI, PPGL, PCGI or stainless steel
Seal
EPDM gasket all round the leaf

Frame and fittings

Frame
Extruded aluminium, GI powder coated or stainless steel
Operation
Manual or motorised
Options
Vision glass, kick plate, push plate

Sizes and range

Temperature
0°C to +10°C. Colder rooms: cold room doors
Door types
Hinged single or double, manual or motorised sliding, hatch
Hinged
750–1000 W × 2000–2400 H mm
Sliding
900–3000 W × 2100–3600 H mm

Rooms that run at chiller temperature

Each one has its own temperature range and its own cleaning routine, and the door is specified to match.

From your drawing to a working door

Four steps, one team, from your first message to a door that closes on its seal.

Measure

You share the openingSend the clear opening size, room temperature, what is stored and how goods move in. A drawing or a phone photo is enough to start.

Specify

We set the doorDoor type, leaf thickness, skin, frame, hardware and options are agreed with you and written into one approved specification.

Build

Made in HosurEach door is manufactured to the approved size at our Hosur works in Tamil Nadu, part of the Alfa PEB group, making since 1992.

Fit

Delivered and fittedWe coordinate delivery and give installation support, so the leaf sits square and closes onto its seal.

Our Clients

FAQs

Chiller door FAQs

A chiller room stays above 0°C, so the door needs a thinner leaf (usually 60 or 80 mm) and no heated frame. A freezer door runs below zero and needs a thicker leaf, a heater to stop the seal freezing shut, and often a pressure-relief port.

Hinged doors suit people, crates and small trolleys, and openings up to about one metre. Choose sliding when pallet trucks or forklifts go through, or when there is no room for a leaf to swing into the aisle.

60 mm PUF suits most chillers between +2°C and +10°C. Choose 80 mm for rooms near 0°C, for pharma stores, or where the door faces a hot, humid loading bay.

Ask us for a handle with an inside release, so the door always opens from inside the room even when it is locked from outside.

No. A strip curtain cuts the loss of cold air while the door is open, but only an insulated, sealed door holds the temperature overnight and when the room is closed.

The clear opening width and height, room temperature, what is stored, how goods move in, the number of doors and the site location.

Planning a chiller room?

Send us the opening size, the room temperature and what goes through the door. We'll recommend the right chiller door and share a price.